bercli

seeing beyond the surface

 

 

 

 

 

 

 

 

 

phased-array solutions
consulting services

 

 

 ultrasound
 eddy-current
radiography

 

 

 

nondestructive testing
 medical imaging

MultiX Multi2000 Pocket 8x32 MultiX LF
OEM UT board 8x32 OEM UT board 16x64 OEM EC single channel Pocket 16x64

Back to M2M systems

bercli

Technical specifications  

M2M

Multiplexed architecture: 16x64 (pulsers x channels)

Pocket

16x64


Acquisition

  • Hardware acquisition gates; unlimited number of software gates
  • Synchronization of gates
  • Acquisition trigger on event (e.g. threshold, detected echo)
  • Acquisition on user specified trigger (e.g. time, mechanical trigger)
  • Acquisition of raw signals and/or summed data
  • Choice of data acquired (e.g. RF, peaks)
  • Real-time image display during acquisition
  • User definable inspection configuration
  • Public file format for parameters (XML) and data (binary)

Phased-array

  • Customized focusing, electronic scanning, and sectorial scanning
  • Pulse echo and pitch-catch modes
  • Dynamic Depth Focusing
  • Inspection mode: pulse echo with electronic selection of active channels
  • Fast multiplexing of focal laws during electronic scanning
  • Imaging adapted to focusing
  • Corrected images (e.g. linear, sectorial BScan)

Pulsers

  • Adjustable voltage: 10 to 80 V with 1V steps
  • Negative rectangular pulse, adjustable width: 20 ns to 1.2 µs, steps of 2.5 ns
  • Maximum PRF: 30kHz

Receivers

  • Bandwidth: 0.5 to 25 MHz
  • Adjustable gain on each channel from 0 to 80 dB
  • Adjustable analog DAC 80 dB (max. 20 dB/µs) synchronized on events
  • Crosstalk between two channels: gain > 50 dB
  • Maximum input signal amplitude ± 1V  

Digitizer

  • Maximum sampling frequency: 100 MHz (adjustable from 100 MHz to 6.6 MHz)
  • Range: 10bits  
  • Input impedance: 50Ω
  • Global delay: 0 up to 1.6 ms, steps of 10ns
  • Delay laws at transmission/reception: 0 to 20 µs, steps of 2.5 ns
  • Digital and analog FIR filters

Simulation of ultrasonic field, focal law computation

  • Simulation tools (CIVA subset)
  • Complete description of the testing configuration
  • Focal law and associated ultrasonic field computation
  • 3D interactive display

Input-Output

  • USB2 for data transfer
  • 1 FRB (Hypertronix) for phased-array probe
  • Encoders input
  • External power supply input

Platform

  • Software environment: Windows XP
  • Usb2 link between hardware and PC (desktop or laptop)

Compatibility

  • NDT configuration compatible with CIVA
  • MASERA Software: data analysis  

Dimensions

  • Length: 160mm (6.4”)
  • Width: 100mm (4”)
  • Thickness: 30mm (1.2”)